1/2 BSP Timer Control Motor Ball Valve WRAS 0-10 Bar TABVM04S

Brand: Connexion ®

Model: TABVM04S

Dimensions
Width 65.00
Height 100.00
Length 63.00

£80.27 £121.62
Price Ex Vat: £66.89

40 in stock

Description

1/2 inch Time Controlled motor ball valve TABVM04S

Actuator:
Fully programmable Set OPEN and CLOSE times between 99 hours 59 minutes 59 seconds, Initially starts as valve timed Closed then timed Open, can change to Start Valve Open then timed close.

Options:
AR (2 wire control) - Power off valve will Automatically Return to programmed start position via power from internal capacitor.

3 wire control - Power off valve stays put, power on valve returns to programmed start position.

Voltages: 9 to 24 volt AC/DC or 110 to 240 Volt AC.
Cycle life: 100,000 open/close
Power: 5 Watts when moving
Open or close time: 5 seconds
Protection: IP67
Temperature: -15°C to +50°C ambient.
Voltage: 9 to 24 volt AC/DC or 110 to 240 volt AC with multi voltage technology
Includes: visual position indication and LED screen.

Ball Valve:
1/2 BSP thread, option NPT thread
Bore: 15.0mm
Body: 304 stainless steel
Pressure: 0 to 10 Bar
Seals: PTFE + EPDM (WRAS Approved)
Temperature: -15°C to +100°C.
Media: air or water etc suitable for materials of construction.

Set Valve Open Time:
Press and hold SET button for 5 seconds displays t On valve open time

Press middle button to select change 10 hour increment, increase with right button
Press middle button to select change 1 hour increment, increase with right button
Press middle button to select change 10 minute increment, increase with right button
Press middle button to select change 1 minute increment, increase with right button
Press middle button to select change 10 second increment, increase with right button
Press middle button to select change 1 second increment, increase with right button

Set Valve Closed Time:
Press and hold SET button for 5 seconds displays t OFF valve closed time

Press middle button to change 10 hour increment with right button
Press middle button to change 1 hour increment with right button
Press middle button to change 10 minute increment with right button
Press middle button to change 1 minute increment with right button
Press middle button to change 10 second increment with right button
Press middle button to change 1 second increment with right button
To set open press button set button until t On displayed

Change Valve Start Position: Valve Closed or Valve Open
Press SET button for 5 seconds

Press set button through menu t On, t OFF, Pons is displayed (Position Start)
Press right button to Change
Start On (Valve start Open then timed close)
OR
Start OFF (Valve start Closed then timed open)

Add a review of this product