Search Results

Search results for "EVRM-NC-114"

11/4 Motor actuated WRAS brass ball valve 12v, 24v or 100-265v 40 Bar CNX20-114

11/4 Motor actuated WRAS ball valve with Open/Close or Failsafe return actuator CNX20WRASBV114.\n\nActuator: Quarter turn compact IP67 ISO5211 direct mount actuator\nTorque: 25NM Break / 20NM run\nRun time: 10 - 15 seconds\nPower: 15 Watts Open/close, 36 Watts failsafe\nCycle life: 20,000 cycle requires 1 minute after use for cooling.\nAmbient temperature: -20°C to +70°C\nMounting: any position\nVoltage: 12vDC, 24vAC/DC or 100-265vAC/DC.\n\nIncludes visual position dome indicator, manual override facility (Allen key provided), 2 volt free position feed cam adjustable feed back switches and 0.6 Watt anti condensation heater.\n\nOptions to choose:\nPower Open / Power closed, power off will stay put.\n\nFailsafe return: Returns using reserve power - either failsafe closed (power to open) or failsafe open (power to close).\n\nFailsafe Actuator requires 30 second power ON with very first use to charge internal battery, valve will then move when charged as will have enough reserve power to return to start position.\n\nBall valve: WRAS certified\nPort: 11/4 BSP\nOrifice: 32mm\nPressure: 40 Bar Max\nMedia Temperature: +95°C Max\nBody: Brass nickel plated\nSeals: PTFE + Viton\nMedia: air, water, water based fluids, oil + diesel compatible with materials of construction.\n\nSupplied complete assembled and function tested ready to use. Fitted with JST-XH 6S 7 Pin connector for testing purposes, which can be removed and rewired if need be.

116 in stock Model: CNX20WRASBV114

Proof of closure switch for VMR/EVRM Gas Valve PCS

Closed position feed back switch to suit Elektrogas Gas Solenoid Valve series VMR (auto reset) and EVRM (manual reset).\n\nMedia: air and natural gas\nPressure: VMR 500 mBar , EVRM 600 mBar Max \nProtection: IP54 \n\nLoads: \nResistive 250vAC 2 Amp, 120vAC 3A or 30vDC 3A max.\nInductive / Lamp 250vAC 0.3A, 120vAC 0.5A or 30vDC 1A\n\nOptions to choose:\nPCS3 suits VMR/EVRM 3/4 +1\" BSP\nPCS4 suits VMR/EVRM 11/4 + 11/2 BSP\nPCS6 suits VMR/EVRM 2\" BSP\nPCS8 suits VMR/EVRM 21/2 + 3\" PN16 flange\nPCS9 suits VMR/EVRM 4\" PN16 flange\nPCS95 suits VMR/EVRM 5 + 6\" PN16 flange\nPCS98 suits EVRM 8\" PN16 flange\nPCS910 suits EVRM 10\" PN16 flange\nPCS912 suits EVRM 12\" PN16 flange\n\nThe PCS is a mechanically activated switch for monitoring the position of the gas valve plate.\nThis safety device can be fitted to the Elektrogas valves provided with a G1/8 threaded hole. This connection is standard for all our stocked valves DN20 upwards (240vAC only). Typically this is a special option available upon request for models DN50 or smaller.\n\nSpecial ATEX (X), Biogas (J) and 6 Bar (6PCS) options available upon request.

11 in stock Model: PCS

11/4 WRAS water solenoid valve 2/2 normally open 0.5-10 Bar Sirai L282D48-114

11/4 Normally open WRAS approved water solenoid valve Sirai L282D48-11/4\nFunction: 2/2 way normally open (failsafe open - power to close)\nOperation: pressure assisted, requires minimum 0.5 Bar pressure difference\nPressure: 0.5 to 9 Bar differential, Max working 10 Bar\nSeals: EPDM WRAS certified\nPort: 11/4 BSPP thread (ISO 228)\nOrifice: 30mm\nKv flow factor: 15 m3/hr\nAnti water hammer design opens 0.3 to 1.5 seconds, closes 1 to 2 seconds \nCoil: Class F DIN43650A 100% duty rated IP65. \nCoil type: ZA10A\nProtection: IP65 with connector (Included)\nPower: AC Inrush 28VA / Holding 20VA, DC 9 Watts. \nVoltage tolerance +/-10% \nVoltages: 12vDC, 24vDC or 24vAC, 110vAC or 230vAC.

10 in stock Model: L282D48-114

3/4 inch Gas Solenoid Valve Manual Reset Elektrogas EVRMNC2A

3/4 inch gas safety shut off solenoid valve with manual reset Elektrogas EVRMNC2A (EVRM-NC-3/4)\nFunction: 2/2 way normally closed with manual reset, (Option Normally Open EVRMNA2A)\nOperation: direct acting\nPort: 3/4 BSP\nBody: Aluminium\nSeals: NBR based rubber certified for gas (EN549)\nClosing time: < 1 second \nCertified: EN161 Class A Group 2, CE Reg PED/0497/895/07, PED 2014/68/EU (Pressure Equipment Directive), ATEX 2014/34/EU, electromagnet compatibility 2014/30/EU, low voltage directive 2014/35/EU and RoHS II 2011/65/EU. \nPressure: 0 to 600 millibar, option (EVRM6NC2A) 6 Bar\nMedia: Air and Natural Gas and non corrosive gases families 1, 2 and 3 (EN437), option (J) Biogas free of ferrous metals with FPM sealing. \nKvs flow factor: 9.5 cubic meters an hour\nVoltage: 230vAC is standard, option (D) 12vAC/DC, (C) 24vAC/DC or (B)110vAC\nCoil: 12 Watt IP65 100% duty rated Class F DIN43650A (voltage tolerance -15% to +10% \nCoil option: ATEX for use in zones 2 and 22 according to 2014/34/EU ATEX directive. Category II 3 G,D, protection Ex nA IIA T4 Gc X, Ex Tc IIIB T135C Dc X or Ex Tc IIIC T135C Dc X (IP65)\nFilter: Incorporated 600 μm (0,02 in) metal mesh filter to protect valve disc and seals as well as downstream components.\nGauge ports: provided with G1/4 pressure gauge ports on both sides to connect manometers, pressure switches, leak tester or other gas equipment.\nPosition indication: G1/8 connection (Included) to fit CPI mechanical closed position switch PCS3.\n\nThe EVRM-NC-2A 3/4 valve is a manual reset safety valve that is failsafe closed. To open the valve from its closed position, the coil must be energised and the knob pulled to the fully open position. Once opened, the valve can maintain this open position whilst electric current is applied to the coil. In absence of electric current the valve closes rapidly (under 1 second) and remains shut until the reset proceedure is reapplied. Once the causes for the lock have been eliminated, valve must be opened manually as described above.\n\nAll components are designed to withstand any mechanical, chemical and thermal condition occuring during typical service. Effective impregnation and surface treatments have been used to improve mechanical reliability , sealing and corrosion resistance.\n\nValves are 100% tested by computer test machines and are fully warrented.

7 in stock Model: EVRMNC-3/4

1 inch Gas Solenoid Valve Manual Reset Elektrogas EVRMNC3A

1 inch gas safety shut off solenoid valve with manual reset Elektrogas EVRMNC3A (EVRM-NC-1)\nFunction: 2/2 way normally closed with manual reset, (Option Normally Open EVRMNA3A)\nOperation: direct acting\nPort: 1 BSP\nBody: Aluminium\nSeals: NBR based rubber certified for gas (EN549)\nClosing time: < 1 second \nCertified: EN161 Class A Group 2, CE Reg PED/0497/895/07, PED 2014/68/EU (Pressure Equipment Directive), ATEX 2014/34/EU, electromagnet compatibility 2014/30/EU, low voltage directive 2014/35/EU and RoHS II 2011/65/EU. \nPressure: 0 to 600 millibar, option (EVRM6NC3A) 6 Bar\nMedia: Air and Natural Gas and non corrosive gases families 1, 2 and 3 (EN437), option (J) Biogas free of ferrous metals with FPM sealing. \nKvs flow factor: 12 cubic meters an hour\nVoltage: 230vAC is standard, option (D) 12vAC/DC, (C) 24vAC/DC or (B)110vAC\nCoil: 12 Watt IP65 100% duty rated Class F DIN43650A (voltage tolerance -15% to +10% \nCoil option: ATEX for use in zones 2 and 22 according to 2014/34/EU ATEX directive. Category II 3 G,D, protection Ex nA IIA T4 Gc X, Ex Tc IIIB T135C Dc X or Ex Tc IIIC T135C Dc X (IP65)\nFilter: Incorporated 600 μm (0,02 in) metal mesh filter to protect valve disc and seals as well as downstream components.\nGauge ports: provided with G1/4 pressure gauge ports on both sides to connect manometers, pressure switches, leak tester or other gas equipment.\nPosition indication: G1/8 connection (Included) to fit CPI mechanical closed position switch PCS3.\n\nThe EVRM-NC-3A 1\" valve is a manual reset safety valve that is failsafe closed. To open the valve from its closed position, the coil must be energised and the knob pulled to the fully open position. Once opened, the valve can maintain this open position whilst electric current is applied to the coil. In absence of electric current the valve closes rapidly (under 1 second) and remains shut until the reset proceedure is reapplied. Once the causes for the lock have been eliminated, valve must be opened manually as described above.\n\nAll components are designed to withstand any mechanical, chemical and thermal condition occuring during typical service. Effective impregnation and surface treatments have been used to improve mechanical reliability , sealing and corrosion resistance.\n\nValves are 100% tested by computer test machines and are fully warrented.

5 in stock Model: EVRM-NC-1