Electrical Connector 2P+E Form A without circuit IP65 PG9 0-250v

EN 175301-803 (DIN43650A) square electrical connector without circuit for solenoid valves,\nConnection: DIN ISO4400 Form A DIN 43650A 28mm square\nConduit entry: PG9 (cable 6 to 8mm) or M20x1.5mm with grommet removed\nVoltages: 0 to 250 volts AC/DC\nCurrent: 16 Amp maximum\nCircuit: non\nProtection: IP65\n\n2022 model updated with new terminal block, new reference 611-201-0063\n\nIn order to establish a suitable electrical connection, the use of ferrules for fine stranded cables are mandatory. Be aware that the wire (conductor) cross-section affects the maximum current load (Amp) capacity.

4189 in stock Model: DIN2

Electrical Connector 2P+E Form A with Bridge Rectifier IP65 0-230v

EN 175301-803 (DIN43650A) square electrical connector 2pin + earth with full bridge rectifier + varistor for solenoid valves, pins 18mm\nConnection: DIN ISO4400 Form A DIN 43650A 28mm square\nVoltage: 0 to 230 volt\nCurrent: 1.5 Amp maximum\nDesign: standard 2 Piece Black Polyamide PA6 GF30 housing with clear cover\nCircuit: Full bridge rectifier (Converts AC 50/60Hz to DC) and VDR varistor with bipolar circuit protection. Drop off delay: 3mSec Max\nPower consumption: 5mAmp Maximum\nResistance: 4 mOhm maximum.\nConduit entry: PG9 (cable 6 to 8mm) or M20x1.5mm with grommet removed\nSeals: NBR LABS-free 6 Grommet, gasket and cover gasket.\nMax Wire Connection: clamping contact Wire 0.5 to 1.5mm, with wire protecting plate.\nResistance 4 mOhm Max.\nPosition: ground (Earth) position 12h (can be adjusted to 3h, 6h or 9h),\nCentral fixing screw: steel 4.8 zinc plated\nContacts: CuZn, Sn/Cu plated\nTemperature: -25°C to +125°C\nCircuit 08\n\n2022 PCB adjusted to the new terminal block all contacts in the terminal block will have screws.\nNass Magnet Part Number: 611-201-0307\n\nIn order to establish a suitable electrical connection, the use of ferrules for fine stranded cables are mandatory. Be aware that the wire (conductor) cross-section affects the maximum current load (Amp) capacity.

401 in stock Model: DIN2R-ALL

Electrical Connector 2P+2E Form A with cable IP67 0-250v

IP67 Moulded pre-wired electrical connector DIN43650A Form A pins 18mm\nDin 43650A square with 3 or 5 meter black 3 core 0.75mm2 H05WF PVC cable with stripping 30mm, green/yellow, brown and blue in single packaging\nRating: 0-250 volt 10 Amp Max\nProtection: IP67\nMaterials: terminal block PA6 GF30\nPoles 2+2E, ground position 6/12 h, contact distance 18mm\nCircuit: without circuit. \nContacts: CuZn zinc plated

189 in stock Model: DIN3-5mtr

Electrical Connector Form A with 20-65% Energy Saving IP65 12-24vDC

Form A EN 175301-803 12-24vDC Pulse Width Modulating 20% to 65% energy saving electrical DIN connector 611-201-1320.\n\nPWM connector will fully energise the valve solenoid to achieve full inrush current. Then, after approximately 100 milliseconds, the PWM circuit reduces the full voltage to a reliable holding power that needs to be adjusted using the 2-1 jumpers to the holding power required by the solenoid valve coil.\n\nThis achieves considerable energy saving, reduces coil heat rise and extends solenoid coil life.\n\nPWM modulating connector jumper settings for the Hold Power Saving\n00..20%, 01..35%, 10..50%, 11..65%\n\nBuy 50 pcs £24.88 each or 100pcs £14.94 each\n\nSimplified guide to setting up.\nWith the pipe system at full load / pressure, reduce the power in single stages until the coil fails to operate correctly, then go back one step.\nExample starting with (00) 20% reduction, then (01) 35%, (10) 50% and (11) 65%, then if coil stops holding so go back to (10) 50%.\n\nThe power reduction is accomplished through pulses with adjustable modulation via relocation of the electrical jumpers for changes in the output voltage. (default setting 20%)\nOperating voltage: 12-24vDC\nMaximum current: 2.5 Amp\nResistance: <15mOhm\nProtection: diode\nDelay = ca. 150 ms\nSwitching Frequency = 2 kHz at 24vDC,\nPulse Ratio of PWM signal = 4 variations,\nPolarity sensitive = Yes\nOvervoltage protection = No.\n\nFor optimum performance, the solenoid coil technical data and electrical parameters must be observed. The PWM circuit includes a protecting diode at the output, eliminating the switch off power surges from the solenoid coil.\nAdditional protecting components such as VDR and TVS diodes are not required.\n\nQuick Overview\nForm: A (Pin Distance 18mm, with circuit with electronics – PWM, Housing: Opaque (Milky), One Piece M20x1.5mm Thread, Manufacturer: Nass Magnet\nMore Information\nGrommets for 6–8 mm, Terminal block: 2 + ground, clamping contact without protecting plate, Electronics: PWM circuit for power sawing, 12–24VDC, NBR profile gasket, black, Standard central fixing screw, Not assembled and single packed in a plastic bag.

144 in stock Model: DIN2-PWM

Electrical Connector 2P+E Form A Bridge Rectifier Red LED + VDR PG9 IP65 24v 110v 230v

EN 175301-803 (DIN43650A) square electrical connector 2 pin + earth with full bridge rectifier, varistor + LED pins 18mm\nConnection: DIN ISO4400 Form A DIN 43650A 28mm square\nVoltage: 12, 24, 48, 120 or 230 volt\nCurrent: 1 Amp maximum\nDesign: standard 2 Piece Black Polyamide PA6 GF30 housing with clear cover\nCircuit: Full bridge rectifier (Converts AC 50/60Hz to DC) RED LED and VDR varistor with bipolar circuit protection. Option Yellow or Green LED \nDrop off delay: Max 3mSec \nPower consumption: 5mAmp Maximum \nResistance: 4 mOhm maximum. \nConduit entry: PG9 (cable 6 to 8mm) or M20x1.5mm with grommet removed\nSeals: NBR LABS-free 6 Grommet, gasket and cover gasket. \nMax Wire Connection with clamping contact Wire 0.5 to 1.5mm, with wire protecting plate. \nPosition: ground (Earth) position 12h (can be adjusted to 3h, 6h or 9h),\nCentral fixing screw: steel 4.8 zinc plated\nContacts: CuZn, Sn/Cu plated\nTemperature: -25°C to +125°C\nCircuit 09\n\n2022 all contacts in the terminal block will have screws and PCB adjusted to the new terminal block.\n24v 611-201-0308\n230v 611-201-0309\n\nIn order to establish a suitable electrical connection, the use of ferrules for fine stranded cables are mandatory. Be aware that the wire (conductor) cross-section affects the maximum current load (Amp) capacity.

134 in stock Model: DIN2R-LED